Q-Tech & Axtal solutions for Space, Military & High Temperature applications

Q-Tech & Axtal solutions for Space, Military & High Temperature applications

  1. Home
  2. /
  3. POSTS
  4. /
  5. Technology
  6. /
  7. Q-Tech & Axtal solutions...

Q-Tech new Product Overview Booklet combines solutions for Space, Military, & High Temperature applications.

SCREENING TEST & QUALITY CONFORMANCE MIL-PRF-55310 PRODUCTS

Screening tests are standard for all MIL-PRF-55310 products. Q-Tech Corporation will customize screening and test procedures to meet your specific requirements.

For Space level products, Q-Tech offers Screening and Quality Conformance testing in accordance with – or superior to – MIL-PRF-55310 and MIL-PRF-38534. Our application notes describing the differences in these requirements can be found here and here.

Q-Tech Corporation also offers Screening and Quality Conformance testing in accordance with EEE-INST-0002, Level 1 (see option N).

  • INTERNAL VISUAL per MIL-STD-883, Method 2017 and 2032
  • STABILIZATION BAKE (Prior to Seal) per MIL-STD-883, Method 1008, Condition C (150ºC)
  • TEMPERATURE CYCLING per MIL-STD-883, Method 1010, Condition C (-55ºC to 125ºC)
  • CONSTANT ACCELERATION per MIL-STD-883, Method 2001, Condition A (Y1 Axis only, 5000g)
  • FINE LEAK per MIL-STD-883, Method 1014, Condition A1, A1, or B1
  • GROSS LEAK per MIL-STD-883, Method 1014, Condition B2, B3, or C
  • PRE BURN-IN Electrical Test, Output Frequency and Waveform at nominal supply voltage, Specified Load, +23ºC ±1ºC (OPTIONAL)
  • BURN-IN (Load) Energized oscillator, with nominal supply voltage and burn-in load, is tested at 125ºC for 160 or 240 hours min.
  • FINAL ELECTRICAL TEST: Input Current Power, Output Frequency, Output Waveform, and Output Voltage Power are tested

QUALITY CONFORMACE INSPECTIONS (QCI)

Quality Conformance Inspections (QCI) are standard for all MIL-PRF-55310 products. Sample units are tested in accordance with Group A and Group B requirements for inspection lots.

For space level products, Q-Tech offers Screening and Quality Conformance testing in accordance with – or superior to – MIL-PRF-55310 and MIL-PRF-38534.

Our application note describing the differences in these requirements can be found here.

GROUP A

  • ELECTRICAL TEST: Supply Voltage, Input Current, Output Waveform, Output Voltage Power, Rise and Fall Times, Duty Cycle, and Start-Up Time (as required)
  • FREQUENCY-TEMPERATURE STABILITY: Initial Accuracy at Reference Temperature, Initial Frequency-Temperature Accuracy and Frequency-Temperature Tolerance
  • FREQUENCY-VOLTAGE TOLERANCE: Output Frequency is measured when oscillator supply voltage is adjusted to its specified nominal value up to its maximum / minimum values
  • OVERVOLTAGE SURVIVABILITY: Overvoltage of 20% above the maximum specified
  • VISUAL AND MECHANICAL: Verify Material, Design, Construction, Workmanship, Physical Dimensions, and Marking per MIL-PRF-55310
  • SOLDERABILITY TEST: per MIL-STD-202, Method 208

GROUP B

  • AGING TEST: Oscillator is energized in oven for a continuous period of 30 days at 70ºC ±3ºC. The Output frequency is measured within an interval of 72 hours maximum per MIL-PRF-55310

Brochures are available for Market segments with the extensive Q-Tech catalog of oscillators.

View or download the brochures using the links in the table below.

 


Contact: Q-Tech Address : 6161 Chip Ave. – Cypress, CA 90630, US
Phone : (310) 836-7900
Fax : (310) 730-6440
Email: sales@q-tech.com
Web: https://q-tech.com/

Italy Agent: DANILO LAUTA
Via Guido Rossa 34, 00065 – Fiano Romano, ROME, ITALY
Email: d.lauta@protec-semi.comWeb: www.microrel.com
In Partnership with:
Rosenheimer Landstraße 117, D-85521 Ottobrunn-Riemerling, Germany
Phone: +49 (0)89 6602923
Email: sales@protec-semi.de
Web: www.protec-semi.de

CONTACT MODULE